HowToCargoLift
BC 2000 H42-D4
Serial no. 23050007744

- Observe crushing and shearing points!
- Observe clearances!
- Respect the operating position!
For lifting step first on H, then on S. For lowering step first on S, then on H.
Load capacity 2,000 kg at load distance 1,000 mm

Please consider the following loading instructions!

Always position trolleys against the trolley stop
Lower forklift / pallet on platform
Maximum capacity is reduced towards the platforme tip
The forklift and the driver are also included in the load capacity!
The load capacity is decreased with loading on one side
Pre-tension reduces sagging of the platform when loaded. For this purpose, actuate lift longer when approaching the body.
Troubleshooting

Emergency measures if operation is no longer possible:
1. Remove support tube cover and protective bonnet of the eBC Controller

2. Error reset via HardReset on the eBC Controller

Does the error persist? Then:
Emergency operation is only possible if the power supply is available!

3.1 Activate emergency operation: Press keys O and C simultaneously until the acoustic signal stops



3. 2 Signal tone at short intervals - move Cargolift into driving position via function keys

3.3 Deactivate emergency operation: Simultaneously press keys O and C until the signal tone stops
4. Contact your nearest Bär service partner!

Your Cargolift was manufactured and delivered by Bär as described.
We are not aware of any subsequent assembly of further components.